Owing to our competent professionals and robust infrastructure, we have been able to establish ourselves as one of the prime manufacturers and suppliers of Industrial Coupler.
TQC Coupler - Tube ClampTube Quick Connect Coupler is designed for easy installation on the end of straight tubing. Slide the coupler on to the end of straight tubing until seated and push down on the Mechanical lever to make a positive seal. A cam locking device grips properly without damage to Steel, Copper, Brass or any metal Tubing. Can be removed from the Tube for operator safety and blow off or loss of seal connnection by accidental bumping is eliminated. When vacuum and easter oil are being used, contact us for help in selection of correct construction of material for your particular application. - Pipe gripping by a collet chuck does not need any welding.
- Can be used in charging, evacuating and leak testing application.
- Double seal construction for SNUG FIT on and out side surface of pipe ensures excellent sealing and vacuum resistance.
- Fluid flows in either direction from plug or socket.
- Pipe size is same, different fitting can be connected.
Specifications: - Material of construction - Stainless Steel
- Connection Part - 1/4, 3/8
- Working Pressure - 30kg/cm2
- Pressure Resistance - 40kg/cm2
- Suitable Fluid - Freon, Helium, Vacuum, Compress Air, etc.
- Seals Material - HNBR, FKV, Cloroprene, NBR, etc.
|
SQC Coupler - SeriesSingle Shut – Off A SQC coupler designed to be completely interchangeable with other styles of sockets and plugs now in the field. An entirely automatic socket allows the use of other different plug styles within the series. For use with compressed air and end connections upto 1/2” size are available. Easy, automatic push-to-connect designs provide instantaneous connection of air lines. Sleeve guard feature is an extra bonus in addition to higher flow rates. Specifications - Material of Construction : Stainless Steel, Zinc Plated, Alloy Aluminum
- Construction of Seal : FKV, EPDM, HNBR, NBR, etc.
- Working Pressure : 150 PSI
- Withstand Pressure : 250 PSI
- Connection Part : 1/4, 3/8, 1/2, 3/4
- Application : Compressed Air, Nitrogen
- Interchangeability : See Interchange chart
|
Coupler - DS SeriesMicron Double Shut Off Coupler works on simple push & pull principle. To connect the coupler, plug is pushed into socket, it is securely held by the self locking arrangement resulting in positive and leak proof connection. This action simultaneously opens the valve and the flow of fluid starts. To disconnect, pull back the sleeve of the socket, the plug ejects and valve shuts off automatically. Double Shut off Couplers application on fluid line connections like Air, Gases, Liquids, Steam Oil etc., used in Chemical Petroleum, Pharmaceutical, Automotive, Refrigeration and other industrial uses. Specifications : - Material of Construction: Stainless Steel, Gun Metal.
- Size : 1/8, 1/4, 3/8, 1/2, 3/4.
- Working Pressure : 40 Kg/ Cm2
- Pressure Resistance : 60 kg/Cm2
- Suitable Fluid : Air, Gases, Refrigeration, Automotive, etc.
- Seal Material : FVK, NBR, HNBR, EPDM, etc.
|
TGP - CouplerTGP - Coupler TGP Series is developed to tackle the problems caused by variations in outer diameter of the copper tube. Sealing the tube on face of the seals solves this problem.
The tube is inserted after pulling down the sleeve and then black handle is moved to 90o which push the rubber seal to hold the OD of the tube from inside
The tube is sealed on the face of the seals therefore high vaccum application is possible.
Operation is simple, user friendly.
Easy maintenance kit is available for replacing the spares, Please follow the 3 dimensional drawing for replacing the spares provided along with ordered material
Different sealing material is available
Specifications: Material of Construction : Brass ( Partially Stainless Steel )
Construction of Seal : FKV, EPDM, HNBR, NBR, etc.
Working Pressure : 30Kg Cm2
Maximum Pressure : 40 Kg/ Cm2
Connection Part : 1/4, 3/8
Suitable fluid : Refrigerant, Compressed Air, Nitrogen etc
|
Ball CouplerBall type Coupler This model is designed for the refrigerant compressor manufacturer. Features: Simple pull operation . Pull housing sleeve for the insertion of the tube.
The 8-24 ball construction depending on the type of fitting helps to grip the outer diameter of the tube.
Single stage and multistage sealing.
Suitable for high pressure appplication.
Low maintenance cost.
Basic criteria for Custom made models for selection of proper construction materials and seals Media or fluid of transfer into the component has to be prescribed by the buyer.
Flow rate pressure at which the media or fluid is injected into the component has to be prescribed.
Cycle time of each point.
Atmospheric and testing conditions.
End Connetion sizes required for the flow of dluids or media.
|
Twin Tube CouplerTwin Tube Coupler This model is designed for the component used in the Automotive Airconditioning industry. this model is customized for the usage of the buyer. This model is designed for two different or similar ports / points where two couplers cannot be incorporated due to minimum centre distance between the ports. Features: Simple lever operation for clamping
Internal two stage sealing
User-Friendly construction
Solution to test two points at single time for better productivity and quality.
Easy maintenance kit is available for replacing the spares, Please follow the three dimensional drawing for replacing the spares provided along with the ordered material
Basic criteria for Custom made models for selection of proper construction materials and seals Media or fluid of transfer into the component has to be prescribed by the buyer.
Flow rate pressure at which the media or fluid is injected into the component has to be prescribed.
Cycle time of each point.
Atmospheric and testing conditions.
End Connetion sizes required for the flow of dluids or media.
|
Tcc Coupler - Od & Id SealingMicron Collet Coupler is designed for testing and charging applications requiring safe and leak free connections. This model uses a combination of appropriate rubber seals and swift holding collets to provide proper gripping and sealing.These Couplers are well suited for resistive Leak testing systems, Gas Charging, Evacuating and made for a variety of production test applications.Micron has more than 15 years of experience in designing and manufacturing specialized coupler for custom applications.The Cam type handle activates the gripping, sealing, quickly and safely.Each and every fitting is specially sized for its application. Most of the components are made from Stainless Steel and PTFE coated Alloy grade Aluminium for long wear and corrosion resistance.Minimal maintenance is required and worn out seals are easily replaced.Equipment is Mobile, Light Weight, Compact and highly reliable.Pressure can be set by the operator as desired due to its user friendly nature. Specifications : Material of construction : SS 316 & Alloy Aluminum
Connection Part : 1/4 & 3/8
Working Pressure : 30 Kg/Cm2
Suitable Fluid : Refrigerant, Compressed Air, Nitrogen, etc.
Seal Material : FKV, NBR, HNBR, EPDM, etc
|
Healium-Testing-CouplerHelium Testing Coupler This model is designed for the radiator manufacturer. It is incorporated with a specially designed Plug and Socket for the transfer of helium into the component. this assembled product is ready to go through the last stage leak check inside the vaccumized helium chamber . Features: - Two/Four Jaw coupler construction for gripping the component
- Single stage and multistage sealing.
- Specially designed Plug and socket ensured one touch push and pull for the media to transfer
- Suitable for all types of pressure and application.
- Low maintanance cost
- Easy maintenance kit is available for replacing the spares, Please follow the three dimensional drawing for replacing the spares provided along with the ordered material
Basic criteria for Custom made models for selection of proper construction materials and seals - Media or fluid of transfer into the component has to be prescribed by the buyer.
- Flow rate pressure at which the media or fluid is injected into the component has to be prescribed.
- Cycle time of each point.
- Atmospheric and testing conditions.
- End Connetion sizes required for the flow of dluids or media.
|  |
 | IPC Coupler With Thumb LeverIPC Coupler ( Thumb lever ) This model is designed for the heat exchanger. this coupler is equipped with multistage gripping and sealing properties. Features: - Internal pipe clamp series is designed forgripping and sealing the inner diameter of the tube
- This equipment comprises of a thumb lever, metal collets, 'O' rings and a face seal.
- For locking and unlocking simple lever up-down movement.
- Multistage metal collets function to grip the inner diameter.
- Multistage 'O' rings function to seal the inner diameter.
- Face seal provides solution to block the outer diameter and provide leak free testing.
- Suitable for all types of pressure applications.
- Low maintenance Cost.
- Easy maintenance kit is available for replacing the spares, Please follow the three dimensional drawing for replacng the spares provided along with the oedered material.
|
IPC Coupler with Toggle LeverIPC Coupler ( Toggle lever ) This model is designed for the internal grooved flared copper tube. this coupler is equipped with multistage gripping and sealing properties. Features: - Internal pipe clamp series is designed forgripping and sealing the inner diameter of the tube
- This equipment comprises of a thumb lever, metal collets, 'O' rings and a face seal.
- For locking and unlocking simple lever up-down movement.
- Multistage metal collets function to grip the inner diameter.
- Multistage 'O' rings function to seal the inner diameter.
- Face seal provides solution to block the outer diameter and provide leak free testing.
- Suitable for all types of pressure applications.
- Low maintenance Cost.
- Easy maintenance kit is available for replacing the spares, Please follow the three dimensional drawing for replacng the spares provided along with the oedered material.
|  |
 | TCL Coupler - Tube ClampFeatures: - To connect pressure or vacuum lines plain tubes needs to be inserted.
- Brazing or threaded part can be avoided by using TCL Coupler.
- The Coupler is simply pushed over the end of the tube and pressed firmly to the stop position. This provides an effective leakproof sealing.
- The tube can be disconnected merely by pressing down the lever & pulling of the coupler.
- Excellent for water dip testing of heat exchanger coil, can be applied for charging and leak testing application also.
- Very user friendly as a simple thumb operation holds the tube.
|
XL Series CouplerThis coupler is a light weight version of TCL series Features: - To connect pressure or vaccum lines plain tubes need to be inserted
- Brazing or threaded part can be avoided by using
- The coupler is simply pushed over the end of the tube and pressed firmly to the stop position. This provides an effective leak proof sealing.
- The tube can be disconnected merely by pressing down the lever and pulling od the coupler.
- Excellent for water dip testing of heat exchanger coil, can be applied for charging and leak testing application also.
- Very user friendly as a simple thumb operation holds the tube.
- Easy maintenance kit is available for replacing the spares, Please follow the three dimensional drawing for replacing the spares provided along with the ordered material.
- Different sealing material is available.
|  |
 | SLEEK Series - Tube Clamp CouplerSlEEK Series - Tube Clamp Coupler This coupler is a unique of its kind. At times it is observed that the centre distance between the two ports in a single copper tube cannot be managed by the regular TCL Series, in order to provide testing solutions to the user this design has been developed. The functional properties remain the same as TCL-Series. Features: - To connect pressure or vaccum lines plain tube needs to be inserted
- Brazing or threaded part can be avoided by using sleek coupler.
- The coupler is simply pushed over the end of the tube and pressed firmly to the stop position. This provides an effective leak proof sealing.
- The tube can be disconnected merely by pressing down the lever and pulling of the coupler.
- Excellent for water dip testing of heat exchanger coil and can be applied for charging and leak testing application also.
- Very user friendly as a simple thumb operation holds the tube.
- Easy maintenance kit is available for replacing the spares, Please follow the three dimensional drawing for replacing the spares provided along with the ordered material.
- Different sealing material is available.
- Material of Construction : Aluminium, Satinless Steel and Industrial Plastic
- Connection Part : 1/8", 1/4" & 3/8"
- Working Pressure : 25 Kg/Cm2
- Maximum Pressure : 35 Kg/Cm2
- Suitable Fluid :Refrigerants, Nitrogen & Compressed Air etc
- Seal Material: HNBR, FKV, Chloroprene, NBR etc
|
TGPL - Tube ClampFeatures: - TGPL Series is developed to tackle the problems caused by variations in outer diameter of the copper tube. Sealing the tube on face of the seals solves this problem.
- The tube is inserted after pushing down the thumb lever and then black handle is moved to 900which pushes the rubber seal to hold OD of the tube from inside the coupling.
- The tube is sealed on the face of the seals therefore high vacuum application is possible.
- Operation is simple user friendly to the thumb lever and very easy to maintain.
- Different sealing material is available.
Specifications : - Material of construction : Gun Metal & Stainless Steel
- Size : 1/4 , 3/8
- Working Pressure : 30 Kg/Cm2
- Pressure Resistance : 40 Kg/Cm2
- Suitable Fluid : Freon, Helium, Vacuum, Air, Hot air etc.
- Seal Material : HNBR, FKV, Cloroprene, NBR, etc.
|  |
 | Exhaust CouplerExhaust Coupler This model is designed for the auto component maker. Features: - Simple Pull operation. Pull the legs attached to the housing sleeve for the insertion and exertion of the tube.
- The 8-24 ball construction depending on the type of fitting helps to grip the outer diameter of the tube.
- Single stage and multistage sealing.
- Suitable for high pressure application
- Low maintenance cost
- Easy maintenance kit is available for replacing the spares, Please follow the three dimensional drawing for replacing the spares provided along with the ordered material.
Basic criteria for Custom made models for selection of proper construction materials and seals - Media or fluid of transfer into the component has to be prescribed by the buyer.
- Flow rate pressure at which the media or fluid is injected into the component has to be prescribed.
- Cycle time of each point.
- Atmospheric and testing conditions.
- End Connetion sizes required for the flow of dluids or media.
|
Grooming CouplerThis model is designed for the test of the automotive component having the grooves on the outer surface of the fitting. Features: - Simple pull operation. Pull housing sleeve down for the removal of the tube, for insertion simply push the coupler inside the tube.
- Customized internal construction depending on the type of fitting comprises a mixture of metallic and polyner components to grip the diameter of the tube.
- Single stage and multi stage sealing.
- Suitable for high pressure application.
- Low maintanance cost.
- Easy maintenance kit is available for replacing the spares, Please follow the three dimensional drawing for replacng the spares provided along with the oedered material.
Basic criteria for Custom made models for selection of proper construction materials and seals - Media or fluid of transfer into the component has to be prescribed by the buyer.
- Flow rate pressure at which the media or fluid is injected into the component has to be prescribed.
- Cycle time of each point.
- Atmospheric and testing conditions.
- End Connetion sizes required for the flow of dluids or media.
|  |
 | Microspill CouplerThis model is designed for the transfer of the fluid from one end. Basically this equipment has a property to ensure one way fluid transfer and vacuum. Features: - Simple pull operation. Pull housing seal for the insertion.
- Customized internal valve ensures the leak free fluid transfer .
- When ejected the fluid or media remains within the system ensuring no fluid loss.
- Inbuilt valve and valveless designs are available .
- Suitable for high pressure application.
Basic criteria for Custom made models for selection of proper construction materials and seals - Media or fluid of transfer into the component has to be prescribed by the buyer.
- Flow rate pressure at which the media or fluid is injected into the component has to be prescribed.
- Cycle time of each point.
- Atmospheric and testing conditions.
- End Connetion sizes required for the flow of dluids or media.
|
Ball Type CouplerBall type Coupler This model is designed for the refrigerant compressor manufacturer. Features: - Simple pull operation . Pull housing sleeve for the insertion of the tube.
- The 8-24 ball construction depending on the type of fitting helps to grip the outer diameter of the tube.
- Single stage and multistage sealing.
- Suitable for high pressure appplication.
- Low maintenance cost.
Basic criteria for Custom made models for selection of proper construction materials and seals - Media or fluid of transfer into the component has to be prescribed by the buyer.
- Flow rate pressure at which the media or fluid is injected into the component has to be prescribed.
- Cycle time of each point.
- Atmospheric and testing conditions.
- End Connetion sizes required for the flow of dluids or media.
|  |
 | 4 JAW Coupler4- Jaw Coupler This model is designed for the auto component manufacturer. It is incorporated with a special design of 4 Jaws (legs) to ensure proper gripping. This design is the advanced form of gripping solution to two jaws being commonly used. this type of clamping device is restricted to the gripping area available for testing. Features: - Four jaw coupler construction for gripping the component.
- Simple auto push pipe Calmping.
- Multistage sealing for longer durability and productivity.
- Suitable for all types of pressure application.
- Low maintenance cost.
Basic criteria for Custom made models for selection of proper construction materials and seals - Media or fluid of transfer into the component has to be prescribed by the buyer.
- Flow rate pressure at which the media or fluid is injected into the component has to be prescribed.
- Cycle time of each point.
- Atmospheric and testing conditions.
- End Connetion sizes required for the flow of dluids or media.
|
|